PARAMETRIC STUDY OF AN IGBT COLD PLATE AND AFFECT OF DEVICE LEVEL MODELLING ON SYSTEM LEVEL THERMAL PREDICTIONS
(2016-02-29)
In power electronics, as there is continuous increase in performance of the electronic devices, simultaneously the size of the components used in these devices keep on decreasing. This has resulted in increased power ...
MAXIMIZING USE OF AIR-SIDE ECONOMIZATION, DIRECT AND INDIRECT EVAPORATIVE COOLING FOR ENERGY EFFICIENT DATA CENTERS
(2016-05-10)
Data centers house information technology (IT) equipment such as servers and network switches which are vital for our networked modern society by providing digital data storage, data processing and connectivity. Data ...
Performance Evaluation of Plate-fin and Pin-fin Heat Sinks for The Application of Oil Immersion Cooling and Design Optimization of Dynamic Cold Plate for The Application of Warm Water Cooling
(2016-05-10)
In IT industries, to keep server rooms and data centers cool is a constant challenge for hardware developers and the cooling solution providers. Air cooling is the most widely used approach for thermal management of servers ...
Computational Study and Error Analysis of an Integrated Sampling-Probe and Gas-Analyzer for Mixing Measurements in Supersonic Flows
(2016-05-10)
Concentration probes are employed in supersonic flow mixing experiments for binary gas mixture composition measurements. These measurements are fundamental for the advancement of the scramjet technology. While non-intrusive ...
CFD ANALYSIS OF VAPOR CHAMBER WITH MICRO PILLARS AS HEAT SPREADER FOR HIGH POWER ELECTRONIC DEVICES
(2016-05-10)
The recent trend in electronic industry shows that there is large power dissipation from the electronic devices and at the same time their sizes are getting smaller. This large power dissipation takes place in the form of ...
DESIGN CONSIDERATION AND STEADY STATE STUDY OF THRUST BEARINGS IN HIGH SPEED SUBSONIC APPLICATIONS
(2016-05-10)
Thrust bearings are required to perform at high speeds in various turbomachinery applications causing the nature of fluid flow within the bearings to be in high subsonic as well as supersonic regimes. The motivation of ...
OPTIMIZATION OF WATER AND ENERGY USE IN INDIRECT EVAPORATIVE COOLING SYSTEM BY CFD
(2016-12-09)
Data center cooling is becoming important to maintain environmental condition for ITE- Information technology equipment. Conventional evaporative wet cooling media lowers the temperature of the dry bulb temperature of ...
CFD MODELLING OF WET COOLING MEDIA AND DESIGN OPTIMIZATION OF HEAT SINK FOR DATA CENTER APPLICATION
(2016-05-12)
Air cooling is most widely used and economical method of currently available cooling technologies in which heat exchanger plays a vital role in facility designs. Evaporative cooling can be energy efficient than mechanical ...