ATTENTION: The works hosted here are being migrated to a new repository that will consolidate resources, improve discoverability, and better show UTA's research impact on the global community. We will update authors as the migration progresses. Please see MavMatrix for more information.
Show simple item record
dc.contributor.author | Dhavala, Sai Sirisha | en_US |
dc.date.accessioned | 2014-09-17T17:29:41Z | |
dc.date.available | 2014-09-17T17:29:41Z | |
dc.date.issued | 2014-09-17 | |
dc.date.submitted | January 2013 | en_US |
dc.identifier.other | DISS-12226 | en_US |
dc.identifier.uri | http://hdl.handle.net/10106/24735 | |
dc.description.abstract | Microfabrication and microfluidic devices have been recognized as potential platforms for cell-based and drug screening studies. Human glioblastoma multiforme (hGBM) cells migrate inside the central nervous system (CNS) in narrow space constrictions and rarely metastasize through bloodstream. Hence, microfluidic devices consisting of narrow channels are considered as suitable models to study cell migration in vitro. Further the migratory capability of each individual cell could be easily obtained and quantified using such system. This effort presents the design and development of an alternative microfluidic system that provides an integrated array of channels for screening multiple drugs simultaneously. This system is an altered version of traditional system, where a single unit is replaced with multiple units to achieve high-throughput multi-screening platform. The device is tailored to screen various types and doses of drugs simultaneously thus increasing its efficiency. This design has the advantage of using multiple types of drugs of varying concentrations to simultaneously study their effectiveness to inhibit cancer cell migration. Using this platform the migration characteristics of cancer cells in response to various anti-cancer drugs is investigated as part of this research effort. Also, the therapeutic potential of anti-cancer drugs were evaluated quantitatively, in comparison with standard cancer migration (scratch wound) assay. | en_US |
dc.description.sponsorship | Kim, Young-Tae | en_US |
dc.language.iso | en | en_US |
dc.publisher | Biomedical Engineering | en_US |
dc.title | Design, Fabrication And Evaluation Of A Novel Microfluidic Based In Vitro Cell Migration Assay | en_US |
dc.type | M.S. | en_US |
dc.contributor.committeeChair | Kim, Young-Tae | en_US |
dc.degree.department | Biomedical Engineering | en_US |
dc.degree.discipline | Biomedical Engineering | en_US |
dc.degree.grantor | University of Texas at Arlington | en_US |
dc.degree.level | masters | en_US |
dc.degree.name | M.S. | en_US |
Files in this item
- Name:
- Dhavala_uta_2502M_12226.pdf
- Size:
- 2.123Mb
- Format:
- PDF
This item appears in the following Collection(s)
Show simple item record