MEASUREMENT OF THE THERMAL PERFORMANCE OF A SINGLE-PHASE IMMERSION COOLED SERVER AT ELEVATED TEMPERATURES FOR PROLONGED TIME
(2018-05-22)
Fully immersion of servers in electrically non-conductive (dielectric) fluid has recently become a promising technique for minimizing cooling energy consumption in data centers. The improved thermal properties of these ...
CFD Analysis of Thermal Shadowing and Optimization of Heat sinks in 3rd generation Open compute server for single phase immersion cooling applications
(2018-05-24)
In today’s networking world, utilization of servers and data center has been increasing significantly. Increasing demands of processing and storage of data causes corresponding increase in power density of servers. The ...
Accelerated Thermal Cycling of Printed Circuit Board for Single Phase Immersion Cooling systems
(2018-05-24)
The adoption of immersion cooling of data center over conventional air-cooling is one among the more up to date advances that individuals have begun embracing to. Acknowledgement of Single phase Liquid Immersion cooling ...
THERMAL DEGRADATION OF PASSIVE COMPONENTS FOR USE IN SINGLE PHASE IMMERSION COOLING APPLICATION
(2018-05-24)
The growth in the computing and data industry demands high-performance data centers where the thermal management issues are of greater concern. A cooling system paradigm using the immersion cooling technology is a more ...
Impact of Immersion Cooling on Thermo-Mechanical Properties of PCB's and Reliability of Electronic Packages
(2019-05-17)
Immersion cooling technique is used for the thermal management of high-density data centers to avoid overheating of components and failure of servers. However, to use this as a viable cooling technique, the effect of ...
COMPUTATIONAL ANALYSIS FOR THERMAL OPTIMIZATION OF SERVER FOR SINGLE - PHASE IMMERSION COOLING
(2019-05-13)
Complete immersion of servers in synthetic dielectric fluids is rapidly becoming a popular technique to minimize the energy consumed by data centers for cooling purposes. In general, immersion cooling offers noteworthy ...
CHARACTERIZING CONTAMINATION TO EXPAND ASHRAE ENVELOPE IN AIRSIDE ECONOMIZATION AND THERMAL AND RELIABILITY IN IMMERSION COOLING OF DATA CENTERS
(2018-08-24)
The Datacom facility which comprises rooms or closets used for communication, computers/servers or electronic equipment requires cooling unit which consumes 31% (23% HVAC cooling + 8% HVAC fans) of overall energy. The ...
DEVELOPMENT OF A METHODOLOGY AND SAMPLE PREPARATION TO EVALUATE RELIABILITY OF OIL COOLED DATA CENTER
(2015-12-10)
Liquid immersion cooling is not a new concept which is slowly emerging as an alternative solution to conventional chilled air cooling systems for data centers. The main idea is to build a body of knowledge to help industry ...
NON THERMAL RELIABILITY CONSIDERATIONS FOR OIL COOLED DATA CENTERS AND ITS SERVICEABILITY
(2015-12-09)
The interest in Oil immersion cooling is increasing day by day which can be attributed to the recent research that shows the potential of its performance when compared to other techniques that add a little more expenses ...