MAXIMIZING USE OF AIR-SIDE ECONOMIZATION, DIRECT AND INDIRECT EVAPORATIVE COOLING FOR ENERGY EFFICIENT DATA CENTERS
(2016-05-10)
Data centers house information technology (IT) equipment such as servers and network switches which are vital for our networked modern society by providing digital data storage, data processing and connectivity. Data ...
Thermal Energy Storage for Expanded Use of Data Center Indirect/Direct Evaporative Cooling
(2016-08-10)
Computer cooling system design evolved over time with goals of increasing efficiency and decreasing cost. Early computers were essentially hand-built and very expensive. Reliable operation required aggressive cooling to ...
DESIGN AND OPTIMIZATION OF THERMAL MANAGEMENT APPROACHES IN DATA CENTER APPLICATIONS
(2020-01-14)
In the present day to day life, Internet of Things (IOT) is everything, i.e., Internet and telecommunication is needed for almost every task of our life, which require data centers. These data centers provide various ...
COOLING EFFICIENCY IMPROVEMENT OF A DATA CENTER USING OPTIMIZED CABINET DESIGN AND HYBRID COOLING WITH HIGH INLET CONDITIONS OF SINGLE-PHASE COOLANT AND AIR
(2021-05-15)
The objective of this study is to improve and optimize the cooling efficiency of liquid and air cooling from server to room level while applying best practices in the industry. The effect of increased air and coolant ...
THE EFFECTS OF TEMPERATURE AND RELATIVE HUMIDITY ON EXPOSURE OF LEGACY AND FUTURE TECHNOLOGY HARDWARE, UNDER REAL DATA CENTER CONDITIONS IN AN ANSI/ISA CLASSIFIED G2 ENVIRONMENT
(2016-08-12)
It is well established that it is safe to operate information technology (IT) equipment in a G1 classified contaminant severity level when operating within specified ASHRAE recommended and allowable limits in an air-side ...
Cold Plate Based Dynamic Liquid Cooling at Data Center and Chip Level
(2022-07-26)
The rising demand for high-performance central and graphical processing units has resulted in the need for more efficient thermal management techniques like direct-to-chip liquid cooling. Direct Liquid Cooling using cold ...
DESIGN, OPERATION AND MAINTENANCE OF DIRECT AND INDIRECT EVAPORATIVE COOLING SYSTEMS IN DATA CENTER THERMAL MANAGEMENT
(2021-08-16)
Evaporative cooling is an alternative data center cooling solution that presents significant energy cost savings in acquisition and operation when compared to conventional air conditioning and mechanical refrigeration ...
Assessment Of Contaminant Flowpaths In Airside Economization And Analysis Of Thermal Performance At Tank And Server Level For Single-phase Immersion Cooled Data Centers
(2022-05-03)
The last two decades of 2000 have seen an explosion of utilization and reliance on digital technologies and platforms. During this time, electronic devices have undergone intense miniaturization and a corresponding rise ...