dc.description.abstract | Modern day data centers are operated at high power for increased power density, maintenance, and cooling which covers almost 2 percent (70 billion kilowatt-hours) of the total energy consumption in the US. IT components and cooling system occupy the major portion of this energy consumption. Although data centers are designed to perform efficiently, cooling the high-density components is still a challenge. So, alternative methods to improve the cooling efficiency has become the drive to reduce the cooling cost. As liquid cooling is more efficient for high specific heat capacity, density, and thermal conductivity, hybrid cooling can offer the advantage of liquid cooling of high heat generating components in the traditional air-cooled servers. In this experiment, a 1U server is equipped with cold plate to cool the CPUs while the rest of the components are cooled by fans. In this study, predictive fan and pump failure analysis are performed which also helps to explore the options for redundancy and to reduce the cooling cost by improving cooling efficiency. The ASHRAE guidance class W4 for liquid cooling is chosen for experiment to operate in a range from 25°C - 45°C. The experiments are conducted separately for the pump and fan failure scenarios. Computational loads are applied while powering only one pump and the miniature dry cooler fans are controlled externally to maintain constant inlet temperature of the coolant. As the rest of components such as DIMMs & PCH are cooled by air, maximum utilization for memory is applied while reducing the number fans in each case for fan failure scenario. The components temperatures and power consumption are recorded in each case for performance analysis. | |
dc.format.mimetype | application/pdf | |
dc.language.iso | en_US | |
dc.subject | Cooling | |
dc.subject | Hybrid cooled server | |
dc.subject | Power consumption | |
dc.subject | Warm water cooling | |
dc.title | THERMAL CHARACTERIZATION OF AN ISOLATED HYBRID COOLED SERVER WITH PUMP AND FAN FAILURE SCENARIOS | |
dc.type | Thesis | |
dc.degree.department | Mechanical and Aerospace Engineering | |
dc.degree.name | Master of Science in Mechanical Engineering | |
dc.date.updated | 2017-10-23T20:03:17Z | |
thesis.degree.department | Mechanical and Aerospace Engineering | |
thesis.degree.grantor | The University of Texas at Arlington | |
thesis.degree.level | Masters | |
thesis.degree.name | Master of Science in Mechanical Engineering | |
dc.type.material | text | |
Files in this item
- Name:
- CHOWDHURY-THESIS-2017.pdf
- Size:
- 13.54Mb
- Format:
- PDF
This item appears in the following Collection(s)
Show simple item record