dc.description.abstract**Please note that the full text is embargoed until 02/01/2026** Identification of tissue viscoelastic properties could provide valuable information for assessing its healthiness or disease state. Current technologies present challenges to access and perform localized tissue assessment in confined spaces in the human body through contact indentation/palpation. As such, there is a need for a diagnostic system capable of measuring tissue relaxation response at the local site by accessing the tissue through a natural orifice. This dissertation presents a strain gauge-based uniaxial micro-force sensor, part of the aforementioned system, capable of measuring tissue response data in confined human space environments. A sensing system design methodology is developed and presented. The sensor operational requirements are used to define design specifications and constraints. An exhaustive search discrete optimization approach is formulated, and finite element analysis is employed to identify optimal sensor component design values. A micro-force sensor with an overall diameter of approximately 3.5mm was prototyped and characterized. Characterization test beds were developed in-house to evaluate the performance of the prototyped micro-force sensor using experimentally collected equivalent force data. The performance of the sensor as it relates to its load-bearing capacity, resolution, sensitivity, accuracy, precision, repeatability error, and hysteresis were evaluated to be 1.07N, 0.13mN, 859.7 μϵ/N , ±28.6mN, 87.2% (23mN), ±3.13% (±25mN), and 118mN respectively. The characterized micro-force sensor was subsequently employed to perform in vivo tissue characterization experiments on the human forearm through normal contact palpation at different control indentation depths and indentation rates according to approved Institutional Review Board protocol 2023-0306. Tissue characterization experiments were performed on 30+ participants ranging in age (20 to 79 years old), race (Asian, Caucasian, Others), gender (male, female), and arm strength training (exercise) or not. A three-element Maxwell-Wiechert viscoelastic model, commonly used for soft tissue characterization, was employed to evaluate the viscoelastic parameters of instantaneous shear modulus and relaxation time constant. The analysis of the results showed that the tissue became compliant as one aged. No identifiable differences were observed for the viscoelastic properties of the tissue as a function of race. The result revealed that females exhibited relatively stiffer tissue. Individuals associated with arm strength training had stiffer tissue. The experimental results provide confidence to employ the sensor to distinguish healthy from diseased tissue in vivo. The dissertation concludes with the importance of this research as a component of a diagnostic system along with a discussion on future research direction.
dc.format.mimetypeapplication/pdf
dc.language.isoen_US
dc.subjectMedical diagnostic device
dc.subjectMicro-force sensor
dc.subjectDesign
dc.subjectOptimization
dc.subjectCharacterization
dc.subjectPrototype
dc.subjectTissue characterization
dc.titleOn the Development of a Sensing System Methodology to Evaluate the Viscoelastic Properties of Soft Tissues as a Means of Disease Prognosis
dc.typeThesis
dc.date.updated2024-01-31T19:40:10Z
thesis.degree.departmentMechanical and Aerospace Engineering
thesis.degree.grantorThe University of Texas at Arlington
thesis.degree.levelDoctoral
thesis.degree.nameDoctor of Philosophy in Mechanical Engineering
dc.type.materialtext
dc.creator.orcid0000-0002-3265-8136
local.embargo.terms2025-12-01
local.embargo.lift2025-12-01


Files in this item

Thumbnail


This item appears in the following Collection(s)

Show simple item record