Performance Evaluation of Plate-fin and Pin-fin Heat Sinks for The Application of Oil Immersion Cooling and Design Optimization of Dynamic Cold Plate for The Application of Warm Water Cooling
(2016-05-10)
In IT industries, to keep server rooms and data centers cool is a constant challenge for hardware developers and the cooling solution providers. Air cooling is the most widely used approach for thermal management of servers ...
COMPARATIVE CFD ANALYSIS OF THE EFFECT OF AIR AND LIQUID COOLING ON THE FORM FACTOR OF GPU SERVER
(2019-08-12)
Artificial intelligence (AI) has becoming an important area which may significantly impact everyone’s daily life. This means a lot of high-performance chips such as high-performance CPU, GPU, FPGA (Field-programmable gate ...
CHARACTERIZATION OF A COLD PLATE BY EXPERIMENTAL ANALYSIS AND POWER SAVINGS CALCULATION OF DYNAMIC COLD PLATE
(2018-05-23)
Cooling is a critical part of data center’s infrastructure, and with ongoing demands in data processing and storage, thermal management issues are of great concern. Some imperative methods of removing heat are either using ...
Experimental and analytical study of a self-regulated Flow Control Device developed for dynamic cold-plates to cool high-power density multi-chip modules
(2019-11-21)
Modern high-power density modules often demand high amounts of power be
invested in their cooling processes. Uneven heating at the chip level creates hotspots
and temperature gradients across the module. A very effective ...
DESIGN AND CFD ANALYSIS OF BIMETALLIC BASED PASSIVE DYNAMIC COLD PLATE FOR HIGH POWER DIRECT-TO-CHIP LIQUID COOLING
(2021-08-18)
Rising demand for high-performance chips results in the need for advanced and efficient cooling technologies like direct to chip liquid cooling. Cold plates based utilizing direct liquid cooling is one of the most efficient ...
COMPUTATIONAL ANALYSIS FOR THERMAL OPTIMIZATION OF SERVER FOR SINGLE - PHASE IMMERSION COOLING
(2019-05-13)
Complete immersion of servers in synthetic dielectric fluids is rapidly becoming a popular technique to minimize the energy consumed by data centers for cooling purposes. In general, immersion cooling offers noteworthy ...
COOLING EFFICIENCY IMPROVEMENT OF A DATA CENTER USING OPTIMIZED CABINET DESIGN AND HYBRID COOLING WITH HIGH INLET CONDITIONS OF SINGLE-PHASE COOLANT AND AIR
(2021-05-15)
The objective of this study is to improve and optimize the cooling efficiency of liquid and air cooling from server to room level while applying best practices in the industry. The effect of increased air and coolant ...
Experimental Study of Dynamic Cooling of Racks using Flow Control Devices
(2020-06-10)
A data center is a cluster of multiple servers that a company uses to store and process large amounts of data. Due to never-ending demands, the processor densities are increasing every day. A higher processor density would ...
Cold Plate Based Dynamic Liquid Cooling at Data Center and Chip Level
(2022-07-26)
The rising demand for high-performance central and graphical processing units has resulted in the need for more efficient thermal management techniques like direct-to-chip liquid cooling. Direct Liquid Cooling using cold ...
DESIGN, OPERATION AND MAINTENANCE OF DIRECT AND INDIRECT EVAPORATIVE COOLING SYSTEMS IN DATA CENTER THERMAL MANAGEMENT
(2021-08-16)
Evaporative cooling is an alternative data center cooling solution that presents significant energy cost savings in acquisition and operation when compared to conventional air conditioning and mechanical refrigeration ...