Computational Study and Optimization of Wet Cooling Media in Direct Evaporative Heat Exchanger
(2017-01-13)
Evaporative cooling media pads are the primary component of importance in direct evaporative cooling units. To increase the overall efficiency of direct evaporative cooling systems, a wet cooling media pad is considered ...
APPLICATION OF ARTIFICIAL NEURAL NETWORK FOR EVAPORATIVE COOLING IN DATA CENTRES
(2017-01-17)
A data center is a facility that may be used to house telecommunication or storage devices. Because of the 24/7 required operation of a data center, large segments of a data center are geared towards evacuating heat generated ...
An Open Source APP-HARDWARE setup to control the system for DATA CENTER COOLING
(2016-12-20)
Control systems for data center cooling exists in the proprietary form and are often sold as part of the overall unit. They provide vital information related to the cooling systems and supply information on the temperature ...
Evaluation of Water consumption and savings achieved in Datacenters through Air side Economization
(2017-01-13)
Recent researches and a few facility owners have focused on eliminating the chiller plant altogether by implementing ‘Evaporative Cooling’, as an alternative or augmentation to compressor-based air conditioning since the ...
THERMAL DESIGN ANALYSIS OF SERVER CHASSIS MANIFOLDS FOR LIQUID COOLED SERVERS USING CFD
(2021-05-18)
Direct-to-chip liquid cooling is one of the most popular methods in data center thermal management when it comes to cooling high chip power densities. A cold plate-based liquid cooling system contains various components ...
DESIGN AND OPTIMIZATION OF THERMAL MANAGEMENT APPROACHES IN DATA CENTER APPLICATIONS
(2020-01-14)
In the present day to day life, Internet of Things (IOT) is everything, i.e., Internet and telecommunication is needed for almost every task of our life, which require data centers. These data centers provide various ...
THERMAL DESTRATIFICATION OF AIR STREAMS TO IMPROVE THE COOLING PROVISIONING OF AIR-COOLED DATA CENTERS
(2019-06-03)
Air side economization is an arrangement of duct, damper and automatic control system which together allow introducing outside air to reduce the mechanical cooling during mild or cold weather thereby decrease the energy ...
Development and Validation of the Deliquescent Relative Humidity Test Method For the Accumulated Particulate Matter Found in a Data Center Utilizing an Airside Economizer
(2018-05-17)
Data centers are virtual or physical infrastructure utilized by enterprises to house computer, server and networking systems and other vital components for the needs of the company’s information technology mainly serving ...
Airflow Path and Flow Pattern Analysis of Sub-Micron Particulate Contaminants in a Data Center with Hot Aisle Containment System Utilizing Direct Air Cooling
(2018-05-22)
The percentage of the energy used by data centers for cooling their equipment has been on the rise. With it has been the necessity for exploring new and more efficient methods, both from an engineering as well as business ...
COOLING EFFICIENCY IMPROVEMENT OF A DATA CENTER USING OPTIMIZED CABINET DESIGN AND HYBRID COOLING WITH HIGH INLET CONDITIONS OF SINGLE-PHASE COOLANT AND AIR
(2021-05-15)
The objective of this study is to improve and optimize the cooling efficiency of liquid and air cooling from server to room level while applying best practices in the industry. The effect of increased air and coolant ...