An Open Source APP-HARDWARE setup to control the system for DATA CENTER COOLING
(2016-12-20)
Control systems for data center cooling exists in the proprietary form and are often sold as part of the overall unit. They provide vital information related to the cooling systems and supply information on the temperature ...
Evaluation of Water consumption and savings achieved in Datacenters through Air side Economization
(2017-01-13)
Recent researches and a few facility owners have focused on eliminating the chiller plant altogether by implementing ‘Evaporative Cooling’, as an alternative or augmentation to compressor-based air conditioning since the ...
Development and Validation of the Deliquescent Relative Humidity Test Method For the Accumulated Particulate Matter Found in a Data Center Utilizing an Airside Economizer
(2018-05-17)
Data centers are virtual or physical infrastructure utilized by enterprises to house computer, server and networking systems and other vital components for the needs of the company’s information technology mainly serving ...
Airflow Path and Flow Pattern Analysis of Sub-Micron Particulate Contaminants in a Data Center with Hot Aisle Containment System Utilizing Direct Air Cooling
(2018-05-22)
The percentage of the energy used by data centers for cooling their equipment has been on the rise. With it has been the necessity for exploring new and more efficient methods, both from an engineering as well as business ...
THE EFFECTS OF TEMPERATURE AND RELATIVE HUMIDITY ON EXPOSURE OF LEGACY AND FUTURE TECHNOLOGY HARDWARE, UNDER REAL DATA CENTER CONDITIONS IN AN ANSI/ISA CLASSIFIED G2 ENVIRONMENT
(2016-08-12)
It is well established that it is safe to operate information technology (IT) equipment in a G1 classified contaminant severity level when operating within specified ASHRAE recommended and allowable limits in an air-side ...
EXPERIMENTAL AND COMPUTATIONAL STUDY OF THE ACCLIMATION OF NEW IT EQUIPMENT
(2017-05-22)
Acclimation of newly commissioned IT equipment is an important step that is necessary for safe operations. Proper acclimation is required to prevent an unnecessary condensation from forming and causing premature failure ...
CHARACTERIZATION OF VERTICALLY SPLIT DISTRIBUTION-WET COOLING MEDIA USED IN DATA CENTERS
(2017-05-24)
Data Centers houses substantial number of information technology (IT) equipment like computer servers and storage modules associated with various electronic components which consume high volume of electricity. The IT ...
EXPERIMENTAL AND COMPUTATIONAL INVESTIGATION OF THE NEED FOR AN ACCLIMATION FOR OPERATING IT EQUIPMENT
(2017-05-22)
Acclimation of IT equipment is not only for newly commissioned equipment but are also for the equipment that is already in use. In conventional Data Center, IT Equipment are cooled by traditional cooling methods, but due ...
Rack Level Study of Hybrid Cooled Servers Using Warm Water Cooling with Variable Pumping for Centralized Coolant System
(2017-05-24)
As the worldwide demand for the data centers grows, so does the size and load placed on data centers which leads to the applied constraints on power and space available to the operator. Cooling power consumption is a major ...
EXPERIMENTAL STUDY ON EFFECTS OF SEGREGATED COOLING PROVISIONING ON THERMAL PERFORMANCE OF INFORMATION TECHNOLOGY SERVERS IN AIR COOLED DATA CENTERS
(2015-12-07)
Modern Information Technology (IT) equipment are typically assumed to operate in quiescent airflow conditions in an uncontained data center facility. In this study, the multi-scaled thermal management strategies are ...