CFD ANALYSIS ON LIQUID COOLED COLD PLATE USING COPPER NANOPARTICLES
(2020-06-05)
In today’s world, most data centres have multiple racks with numerous servers in each of them. The high amount of heat dissipation has become the largest server-level cooling problem for the data centres. The higher ...
Experimental Study of Dynamic Cooling of Racks using Flow Control Devices
(2020-06-10)
A data center is a cluster of multiple servers that a company uses to store and process large amounts of data. Due to never-ending demands, the processor densities are increasing every day. A higher processor density would ...
SENSITIVITY STUDY OF CALIBRATED DATA CENTER MODELS TO MINIMIZE SITE SURVEY TIME USING CFD
(2021-05-12)
Data center (DC) consists of components like cooling pipes, data cables, power conduits, etc. To analyze the thermal behavior of DC using computational fluid dynamics, virtual model of DC is required. To build this virtual ...
OPTIMIZING THE DEMAND AND DISTRIBUTION OF POWER IN SMART GRIDS
(2021-08-16)
The electricity is generated in bulk power plants and transported to the end-user through the transmission and distribution networks. The process incurs heavy losses adding to the operational costs. Secondly, fossil fuels ...
THE EFFECTS OF TEMPERATURE AND RELATIVE HUMIDITY ON EXPOSURE OF LEGACY AND FUTURE TECHNOLOGY HARDWARE, UNDER REAL DATA CENTER CONDITIONS IN AN ANSI/ISA CLASSIFIED G2 ENVIRONMENT
(2016-08-12)
It is well established that it is safe to operate information technology (IT) equipment in a G1 classified contaminant severity level when operating within specified ASHRAE recommended and allowable limits in an air-side ...
Cold Plate Based Dynamic Liquid Cooling at Data Center and Chip Level
(2022-07-26)
The rising demand for high-performance central and graphical processing units has resulted in the need for more efficient thermal management techniques like direct-to-chip liquid cooling. Direct Liquid Cooling using cold ...
EXPERIMENTAL AND COMPUTATIONAL STUDY OF THE ACCLIMATION OF NEW IT EQUIPMENT
(2017-05-22)
Acclimation of newly commissioned IT equipment is an important step that is necessary for safe operations. Proper acclimation is required to prevent an unnecessary condensation from forming and causing premature failure ...
CHARACTERIZATION OF VERTICALLY SPLIT DISTRIBUTION-WET COOLING MEDIA USED IN DATA CENTERS
(2017-05-24)
Data Centers houses substantial number of information technology (IT) equipment like computer servers and storage modules associated with various electronic components which consume high volume of electricity. The IT ...
DESIGN, OPERATION AND MAINTENANCE OF DIRECT AND INDIRECT EVAPORATIVE COOLING SYSTEMS IN DATA CENTER THERMAL MANAGEMENT
(2021-08-16)
Evaporative cooling is an alternative data center cooling solution that presents significant energy cost savings in acquisition and operation when compared to conventional air conditioning and mechanical refrigeration ...
Assessment Of Contaminant Flowpaths In Airside Economization And Analysis Of Thermal Performance At Tank And Server Level For Single-phase Immersion Cooled Data Centers
(2022-05-03)
The last two decades of 2000 have seen an explosion of utilization and reliance on digital technologies and platforms. During this time, electronic devices have undergone intense miniaturization and a corresponding rise ...